1. Identificação | |
Tipo de Referência | Artigo em Revista Científica (Journal Article) |
Site | plutao.sid.inpe.br |
Código do Detentor | isadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S |
Identificador | 8JMKD2USNNW/4CNAG9C |
Repositório | sid.inpe.br/plutao/2025/01.08.18.45.37 (acesso restrito) |
Última Atualização | 2025:01.09.16.24.33 (UTC) lattes |
Repositório de Metadados | sid.inpe.br/plutao/2025/01.08.18.45.38 |
Última Atualização dos Metadados | 2025:01.11.01.23.15 (UTC) administrator |
DOI | 10.54033/cadpedv21n8-146 |
ISSN | 1516-6600 |
Rótulo | lattes: 3335657546230527 3 CostaTurcSantFurl:2024:CaVeSe |
Chave de Citação | CostaTurcSantFurl:2024:CaVeSe |
Título | Calibração e verificação de sensores para estimativa da evapotranspiração de referência  |
Ano | 2024 |
Data de Acesso | 11 jul. 2025 |
Tipo de Trabalho | journal article |
Tipo Secundário | PRE PN |
Número de Arquivos | 1 |
Tamanho | 716 KiB |
|
2. Contextualização | |
Autor | 1 Costa, Daniel Aparecido Morello da 2 Turco, José Eduardo Pitelli 3 Santana, Marcio Antonio Aparecido 4 Furlani, Carlos Eduardo Angeli |
Identificador de Curriculo | 1 2 3 8JMKD3MGP5W/3C9JHPG |
Grupo | 1 2 3 COMIT-CGIP-INPE-MCTI-GOV-BR |
Afiliação | 1 Universidade Estadual Paulista (UNESP) 2 Universidade Estadual Paulista (UNESP) 3 Instituto Nacional de Pesquisas Espaciais (INPE) 4 Universidade Estadual Paulista (UNESP) |
Endereço de e-Mail do Autor | 1 daniel.morello@unesp.br 2 jose.turco@unesp.br 3 marcio.santana@inpe.br 4 eduardo.furlani@unesp.br |
Revista | Caderno Pedagógico |
Volume | 21 |
Número | 8 |
Páginas | e6779-e6779 |
Nota Secundária | B3_ENSINO B4_ODONTOLOGIA B4_INTERDISCIPLINAR B4_CIÊNCIAS_AMBIENTAIS B4_BIODIVERSIDADE B5_SOCIOLOGIA B5_EDUCAÇÃO B5_CIÊNCIAS_SOCIAIS_APLICADAS_I C_CIÊNCIAS_AGRÁRIAS_I |
Histórico (UTC) | 2025-01-09 16:24:49 :: lattes -> administrator :: 2024 2025-01-11 01:23:15 :: administrator -> lattes :: 2024 |
|
3. Conteúdo e estrutura | |
É a matriz ou uma cópia? | é a matriz |
Estágio do Conteúdo | concluido |
Transferível | 1 |
Tipo do Conteúdo | External Contribution |
Tipo de Versão | publisher |
Palavras-Chave | Calibração de sensores Incerteza de Medição Metrologia Ambiental evapotranspiração Sensor Calibration Measurement Uncertainty Environmental Metrology Evapotranspiration Calibración de Sensors Incertidumbre en la Medición Metrología Ambiental Evapotranspiración |
Resumo | Com este trabalho o objetivo foi calibrar sensores de uma estação meteorológica automática e verificar os sensores de outra e verificar a influência da calibração de sensores na estimativa da evapotranspiração de referência (ETo). Os dados meteorológicos avaliados foram radiação solar global, temperatura do ar, umidade do ar, velocidade do vento e precipitação pluviométrica. O método de estimativa diária da ETo avaliado foi o de Penman-Monteith (PM), recomendado pela FAO como método padrão para estimar a ETo. Os dados meteorológicos foram obtidos por duas estações meteorológicas automáticas: da marca Davis Instruments (EMA-DI) e da marca Campbell Scientific, calibrada (EMA-C). Asduas estações foram instaladas na área experimental do LIAP (Laboratório de Instrumentação Automação e processamento) do Departamento de Engenharia da Universidade Estadual Paulista (UNESP), Faculdade de Ciências Agrárias e Veterinárias, Jaboticabal, situada a 2101522 S, 4801858 O. Foi utilizada metodologia que possui as seguintes técnicas: estimativa da radiação solar global, dupla massa, comparabilidade operacional de medições meteorológicas, assimetria e curtose, para verificar os dados da EMA-DI em relação a EMA-C. Foram estimadas a ETo com os dados meteorológicos das duas EMAs. No período estudado os sensores calibrados não influenciaram estimativa da ETo pelo método de PM, mas influenciaram na incerteza da estimativa da ETo (±ETo). ABSTRACT: With this work the objective was to calibrate sensors of an automatic meteorolog-ical station and verify the sensors of another and verify the influence of sensor calibration on the estimation of reference evapotranspiration (ETo). The meteor-ological data evaluated were global solar radiation, air temperature, air humidity, wind speed and rainfall. The daily ETo estimation method evaluated was the Pen-man-Monteith (PM), recommended by FAO as a standard method for estimating ETo. Meteorological data were obtained by two automatic meteorological sta-tions: Davis Instruments (EMA-DI) and Campbell Scientific, calibrated (EMA-C). The two stations were installed inthe experimental area of the LIAP (Instrumen-tation Automation and Processing Laboratory) of the Department of Engineering at São Paulo State University (UNESP), School of Agricultural and Veterinary Sciences, Jaboticabal, located at 2101522 S, 4801858 W. A methodology was used that has the following techniques:estimation of global solar radiation, dou-ble mass, operational comparability of meteorological measurements, asymmetry and kurtosis, to verify the EMA-DI data in relation to EMA-C. During the period studied, the calibrated sensors did not influence the ETo estimate using the PM method, but they influenced the uncertainty of the ETo estimate(±ETo). RESUMEN:Con este trabajo el objetivo fue calibrar sensores de una estación meteorológica automática y verificar los sensores de otra y verificar la influencia de la cali-bración de los sensores en la estimación de la evapotranspiraciónde referencia (ETo). Los datos meteorológicos evaluados fueron la radiación solar global, la temperatura del aire, la humedad del aire, la velocidad del viento y las precipi-taciones. El método de estimación de la ETo diaria evaluado fue el Penman-Monteith(PM), recomendado por la FAO como método estándar para la estimación de la ETo. Los datos meteorológicos fueron obtenidos por dos es-taciones meteorológicas automáticas: Davis Instruments (EMA-DI) y Campbell Scientific, calibradas (EMA-C). Las dos estaciones fueron instaladas en el área experimental del LIAP (Laboratorio de Procesamiento y Automatización de In-strumentación) del Departamento de Ingeniería de la Universidad Estadual Pau-lista (UNESP), Facultad de Ciencias Agrícolas y Veterinarias, Jaboticabal,ubi-cado en 21015'22 S , 48018'58 O. Se utilizó una metodología que incluye las siguientes técnicas: estimación de radiación solar global, doble masa, compara-bilidad operativa de mediciones meteorológicas, asimetría y curtosis, para veri-ficar los datos de EMA-DI con relación a EMA-C. La ETo se estimó con datos meteorológicos de las dos EMA. Durante el período estudiado, los sensores cal-ibrados no influyeron en la estimación de ETo utilizando el método PM, pero sí influyeron en la incertidumbre de la estimación de ETo (±ETo). |
Área | ETES |
Arranjo | urlib.net > BDMCI > Fonds > Produção a partir de 2021 > CGIP > Calibração e verificação... |
Conteúdo da Pasta doc | acessar |
Conteúdo da Pasta source | não têm arquivos |
Conteúdo da Pasta agreement | não têm arquivos |
|
4. Condições de acesso e uso | |
Idioma | pt |
Arquivo Alvo | 146+Caderno+P..pdf |
Grupo de Usuários | lattes |
Grupo de Leitores | administrator lattes |
Visibilidade | shown |
Permissão de Leitura | deny from all and allow from 150.163 |
Permissão de Atualização | não transferida |
|
5. Fontes relacionadas | |
Unidades Imediatamente Superiores | 8JMKD3MGPCW/46KUES5 |
URL (dados não confiáveis) | https://ojs.studiespublicacoes.com.br/ojs/index.php/cadped/article/view/6779 |
Acervo Hospedeiro | dpi.inpe.br/plutao@80/2008/08.19.15.01 |
|
6. Notas | |
Campos Vazios | alternatejournal archivingpolicy archivist callnumber copyholder copyright creatorhistory descriptionlevel dissemination e-mailaddress format isbn lineage mark mirrorrepository month nextedition notes orcid parameterlist parentrepositories previousedition previouslowerunit progress project rightsholder schedulinginformation secondarydate secondarykey session shorttitle sponsor subject tertiarymark tertiarytype |
|
7. Controle da descrição | |
e-Mail (login) | lattes |
atualizar | |
|