Fechar

1. Identificação
Tipo de ReferênciaArtigo em Evento (Conference Proceedings)
Sitemtc-m16d.sid.inpe.br
Código do Detentorisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
Identificador8JMKD3MGP7W/3EPDA77
Repositóriosid.inpe.br/mtc-m19/2013/09.03.16.21.59
Última Atualização2020:08.18.19.56.29 (UTC) simone
Repositório de Metadadossid.inpe.br/mtc-m19/2013/09.03.16.22
Última Atualização dos Metadados2022:07.08.21.12.16 (UTC) administrator
Chave de CitaçãoPintoFern:2013:ImIôIm
TítuloImplantação iônica por imersão em plasma de ligas Ti-Si-B
Ano2013
Data de Acesso01 jun. 2024
Tipo SecundárioPRE CN
Número de Arquivos2
Tamanho3548 KiB
2. Contextualização
Autor1 Pinto, José Paulo Rocha Pereira
2 Fernandes, Bruno Bacci
Grupo1
2 LAP-CTE-INPE-MCTI-GOV-BR
Afiliação1
2 Instituto Nacional de Pesquisas Espaciais (INPE)
Endereço de e-Mail do Autor1 zepereirapinto@hotmail.com
2 brunobacci@yahoo.com.br
Endereço de e-Mailmarcelo.pazos@inpe.br
Nome do EventoSeminário de Iniciação Científica do INPE (SICINPE).
Localização do EventoSão José dos Campos
Data30 e 31 de julho de 2013
Editora (Publisher)INPE
Cidade da EditoraSão José dos Campos
Título do LivroAnais
Histórico (UTC)2013-09-03 16:22:00 :: marcelo.pazos@sid.inpe.br -> administrator ::
2020-04-29 12:37:27 :: administrator -> simone :: 2013
2020-08-18 19:56:30 :: simone -> administrator :: 2013
2022-07-08 21:12:16 :: administrator -> simone :: 2013
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Palavras-Chavemoagem de alta energia
implantação iônica por imersão em plasma
resistência à corrosão
plasma de microondas
tribologia
high energy ball milling
plasma immersion ion implantation
corrosion resistance
microwave plasma
tribology
ResumoEmbora as ligas de titânio possuam boas propriedades mecânicas e excelentes resistências à corrosão, estes materiais apresentam propriedades tribológicas insuficientes para aplicações que exigem resistência ao desgaste. A fim de produzir superfícies resistentes ao desgaste, este trabalho tem como objetivo a melhoria das características tribológicas de ligas Ti-Si-B por meio de implantação iônica por imersão em plasma de nitrogênio em temperaturas elevadas (3IPAT-N). Estas ligas foram produzidas pela metalurgia do pó usando processos de moagem de alta energia e sinterização. Suas microestruturas e composições foram estudadas por meio de microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva (EDS) e difração de raios X (DRX). Ensaios de desgaste foram realizados com um tribômetro tipo ball-on-disc para avaliar o coeficiente de atrito e a taxa de desgaste em amostras tratadas e não tratadas. As larguras das trilhas foram medidas por um microscópio ótico e analisadas por microscopia eletrônica de varredura para determinar os mecanismos de desgaste. Apenas as ligas sinterizadas sem tratamento por 3IP foram analisadas até o momento. Ligas comerciais Ti-6Al-4V também foram tratadas por 3IP para ajudarem em análises comparativas. Neste trabalho também foram iniciadas atividades de pesquisa com plasma de microondas. ABSTRACT: While titanium alloys have good mechanical properties and excellent corrosion resistance, these materials have insufficient tribological properties for applications requiring wear resistance. In order to produce wear resistant surfaces, this work aims to improve the tribological characteristics of Ti-Si-B by means of plasma immersion ion implantation of nitrogen at high temperatures (HTPIII-N). These alloys were produced by powder metallurgy processes using high energy ball milling and sintering. Their compositions and microstructures were studied by means of scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). Wear tests were performed with a ball-on-disc tribometer to evaluate the friction coefficient and wear rate in treated and untreated samples. Track widths were measured by an optical microscope and analyzed by scanning electron microscopy to determine the wear mechanisms. Only untreated Ti-Si-B alloys were analyzed at the moment. Commercial Ti-6Al-4V alloys were also treated by HTPIII-N to assist in comparative analysis. It was also initiated research activities with microwave plasma in the present work.
ÁreaFISPLASMA
Arranjo 1urlib.net > BDMCI > Fonds > Produção anterior à 2021 > LABAP > Implantação iônica por...
Arranjo 2urlib.net > BDMCI > Fonds > Acervo PIBIC/PIBITI > PIBIC/PIBITI 2013 > Implantação iônica por...
Conteúdo da Pasta docacessar
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreement
agreement.html 03/09/2013 13:21 1.0 KiB 
4. Condições de acesso e uso
URL dos dadoshttp://urlib.net/ibi/8JMKD3MGP7W/3EPDA77
URL dos dados zipadoshttp://urlib.net/zip/8JMKD3MGP7W/3EPDA77
Idiomapt
Arquivo AlvoJosé Paulo Rocha Pereira Pinto.pdf
Grupo de Usuáriosmarcelo.pazos@inpe.br
Grupo de Leitoresadministrator
marcelo.pazos@inpe.br
simone
Visibilidadeshown
Detentor da CópiaSID/SCD
Permissão de Atualizaçãonão transferida
5. Fontes relacionadas
Repositório Espelhoiconet.com.br/banon/2006/11.26.21.31
Unidades Imediatamente Superiores8JMKD3MGPCW/3ET2RFS
8JMKD3MGPDW34P/478H8RC
Lista de Itens Citandosid.inpe.br/bibdigital/2013/09.25.21.49 1
sid.inpe.br/mtc-m16c/2022/07.08.19.46.49 1
Acervo Hospedeirosid.inpe.br/mtc-m19@80/2009/08.21.17.02
6. Notas
NotasBolsa PIBIC/INPE/CNPq
Campos Vaziosarchivingpolicy archivist callnumber contenttype copyright creatorhistory descriptionlevel dissemination doi edition editor format isbn issn label lineage mark nextedition numberofvolumes orcid organization pages parameterlist parentrepositories previousedition previouslowerunit progress project readpermission resumeid rightsholder schedulinginformation secondarydate secondarykey secondarymark serieseditor session shorttitle sponsor subject tertiarymark tertiarytype type url versiontype volume
7. Controle da descrição
e-Mail (login)simone
atualizar 


Fechar