Fechar

1. Identificação
Tipo de ReferênciaArtigo em Revista Científica (Journal Article)
Sitemarte3.sid.inpe.br
Código do Detentorisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
Identificador6qtX3pFwXQZ3r59YCT/GT5Su
Repositóriosid.inpe.br/iris@1905/2005/07.26.23.01   (acesso restrito)
Última Atualização2013:04.12.17.45.18 (UTC) jefferson
Repositório de Metadadossid.inpe.br/iris@1905/2005/07.26.23.01.21
Última Atualização dos Metadados2018:06.06.04.11.42 (UTC) administrator
Chave SecundáriaINPE-5029
ISSN0018-9499
Rótulo2942
Chave de CitaçãoBragaCovaGrin:1989:CaPeEn
TítuloCalibration and performace of the energetic x-ray imaging telescope experiment
Ano1989
MêsFeb.
Data de Acesso26 jun. 2024
Tipo SecundárioPRE PI
Número de Arquivos1
Tamanho364 KiB
2. Contextualização
Autor1 Braga, João
2 Covault, Corbin E.
3 Grindlay, J. E.
Grupo1 DAS-INPE-BR
Afiliação1 Instituto Nacional de Pesquisas Espaciais (INPE)
2 Harvard-Smithsonian Center for Astrophysics
3 Harvard-Smithsonian Center for Astrophysics
Endereço de e-Mail do Autor1 joao.braga@das.inpe.br
RevistaIEEE Transactions on Nuclear Science
Volume36
Número1
Páginas871-875
Histórico (UTC)2013-03-19 19:19:49 :: administrator -> jefferson :: 1989
2013-04-12 17:45:18 :: jefferson -> administrator :: 1989
2018-06-06 04:11:42 :: administrator -> marciana :: 1989
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Tipo do ConteúdoExternal Contribution
Tipo de Versãopublisher
Palavras-ChaveEnergetic X-ray Imaging Telescope Experiment (EXITE)
"flat fielding" methods
energy spectra
ResumoThe final integration and testing of the Energetic X-ray Imaging Telescope Experiment (EXITE) is described. The detector and telescope as finally assembled are described, and problems as well as solutions are detailed. The pre-flight calibration of the position sensitive NaI detector revealed interesting effects, not anticipated, in the the energy spectra. In particular, an effect due to surface roughness (lack of firm optical polishing) on the crystal was found and calibrated. The radial variation of gain and resolution in the detector was also measured, and "flat fielding" methods have been derived to analyse the data. The integration of the EXITE detector and gondola systems is described. Several new features were developed for the EXITE gondola - most notably a shock absorbcr system. The performance of the detector and gondola systems was evaluated an a first balloon flight from Australia (May 1988) and a second flight from Ft. Sumner,NM (October 1988).
ÁreaCEA
Arranjourlib.net > BDMCI > Fonds > Produção anterior à 2021 > DIDAS > Calibration and performace...
Conteúdo da Pasta docacessar
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreementnão têm arquivos
4. Condições de acesso e uso
Arquivo Alvo00034568.pdf
Grupo de Usuáriosadministrator
jefferson
Visibilidadeshown
Política de Arquivamentodenypublisher allowfinaldraft
Permissão de Leituradeny from all and allow from 150.163
Permissão de Atualizaçãonão transferida
5. Fontes relacionadas
Unidades Imediatamente Superiores8JMKD3MGPCW/3ETR8EH
DivulgaçãoWEBSCI; PORTALCAPES; COMPENDEX; IEEEXplore.
Acervo Hospedeirosid.inpe.br/banon/2001/04.03.15.36
6. Notas
Campos Vaziosalternatejournal archivist callnumber copyholder copyright creatorhistory descriptionlevel doi e-mailaddress format isbn language lineage mark mirrorrepository nextedition notes orcid parameterlist parentrepositories previousedition previouslowerunit progress project readergroup resumeid rightsholder schedulinginformation secondarydate secondarymark session shorttitle sponsor subject tertiarymark tertiarytype typeofwork url