@InProceedings{DallaquaDelBSilv:1993:EfReGa,
author = "Dallaqua, Renato S{\'e}rgio and Del Bosco, Edson and Silva, R.
P.",
affiliation = "{Instituto Nacional de Pesquisas Espaciais (INPE)} and {Instituto
Nacional de Pesquisas Espaciais (INPE)} and {Instituto Nacional de
Pesquisas Espaciais (INPE)}",
title = "Effects of residual gases in the electron temperature and density
in a vaccum arc plasma centrifuge",
booktitle = "Proceedings...",
year = "1993",
pages = "18--22",
organization = "Encontro Brasileiro de F{\'{\i}}sica dos Plasmas, 2.",
abstract = "Measurements of electron temperature and plasma density were
carried out in a vacuum arc plasma centrifuge to investigate the
influence of residual gases in these parameters. The measurements
were performed in a magnesium plasma utilizing a cylindrical
Langmuir probe. Hidrogen, helium and argon were used a residual
gases with pressure varying in the range of 1x10-4 to 1x10-1 Pa.
With no gas (1x10-4 Pa) the electron temperature and plasma
density are pratically constant over the entire plasma current
pulse. The introduction of a gas change this picture appreciably.
For the range of 10-2 - 10-1 Pa the electron temperature decrease
about 50% while the plasma density increases by the same factor
with regard to the vacuum value, in the initial stage of the
discharge but approaches to the vacuum value at the end of the
discharge.",
conference-location = "Serra Negra",
language = "en",
targetfile = "effects of residual gases.pdf",
urlaccessdate = "27 abr. 2024"
}