@PhDThesis{Ferreira:2018:EsTrCa,
               author = "Ferreira, {\'E}lvis Camilo",
                title = "Estudo do tratamento de cavidades de ni{\'o}bio para o detector 
                         Mario Schenberg e do desempenho do Multi-Nested Pendula para uso 
                         em detectores interferom{\'e}tricos",
               school = "Instituto Nacional de Pesquisas Espaciais (INPE)",
                 year = "2018",
              address = "S{\~a}o Jos{\'e} dos Campos",
                month = "2018-05-30",
             keywords = "ondas gravitacionais, detectores, isolamento vibracional, 
                         multi-nested pendula, antimolas geom{\'e}tricas, transdutores, 
                         gravitational waves, detectors, vibrational isolation, 
                         Multi-Nested Pendula, geometric antisprings, transducers.",
             abstract = "Neste trabalho, apresenta-se o desenvolvimento de instrumentos 
                         para aumentar a sensibilidade de detectores de ondas 
                         gravitacionais. Foi realizada uma investiga{\c{c}}{\~a}o para 
                         otimizar o fator de qualidade el{\'e}trico de cavidades de 
                         ni{\'o}bio, dos transdutores do detector esf{\'e}rico Mario 
                         Schenberg. Processos de ataque qu{\'{\i}}mico por 
                         solu{\c{c}}{\~a}o {\'a}cida e implanta{\c{c}}{\~o}es 
                         i{\^o}nicas por imers{\~a}o em plasma de nitrog{\^e}nio nas 
                         superf{\'{\i}}cies das cavidades foram feitos. O maior fator 
                         obtido foi de cerca de 60 mil. Observa-se que baixos percentuais 
                         at{\^o}micos de nitrog{\^e}nio na superf{\'{\i}}cie s{\~a}o, 
                         provavelmente, um requisito para obten{\c{c}}{\~a}o de altos 
                         fatores de qualidade el{\'e}tricos. Apresenta-se, tamb{\'e}m, 
                         uma investiga{\c{c}}{\~a}o sobre o ru{\'{\i}}do vibracional 
                         tilt de solo induzido pelo vento, no observat{\'o}rio LIGO de 
                         Livingston. Neste trabalho, tamb{\'e}m {\'e} descrito o 
                         desenvolvimento de instrumentos de isolamento vibracional passivo, 
                         para as massas de teste (espelhos) de detectores 
                         interferom{\'e}tricos de ondas gravitacionais, como o LIGO. Mais 
                         especificamente, de um sistema pendular multi-aninhado (MNP) com 
                         antimolas geom{\'e}tricas (GAS). O desenvolvimento incluiu: 
                         estudos sobre o centro de percuss{\~a}o; instala{\c{c}}{\~a}o 
                         de novas suspens{\~o}es; e, tamb{\'e}m, a instala{\c{c}}{\~a}o 
                         de um conjunto de GAS; al{\'e}m da melhora das t{\'e}cnicas de 
                         medi{\c{c}}{\~a}o do sistema em v{\'a}cuo. O efeito antimola de 
                         um prot{\'o}tipo GAS foi observado. Mostra-se, atrav{\'e}s dos 
                         experimentos e das simula{\c{c}}{\~o}es, que a 
                         atenua{\c{c}}{\~a}o do MNP otimizado, chega at{\'e} um fator da 
                         ordem de 10.000. Esse fator ainda poderia ser aumentado com um 
                         novo modelo do sistema. ABSTRACT: In this work, we present the 
                         development of instruments to increase the sensitivity of 
                         gravitational wave detectors. An investigation was carried out to 
                         optimize the electrical Q factor of niobium transducers cavities 
                         of the Mario Schenberg spherical antenna. Chemical processes, and 
                         nitrogen plasma immersion ion implantation on cavities surfaces 
                         were done. The largest Q factor measured was about 60k. It is 
                         observed that low atomic percentages of nitrogen in the surface 
                         probably are a requirement for obtaining high electrical Q 
                         factors. We also present an investigation on the vibrational noise 
                         of the ground-tilt induced by wind in the LIGO Livingston 
                         Observatory. In this work, we also describe the development of 
                         passive vibrational isolation instruments for the test masses 
                         (mirrors) of interferometric gravitational wave detectors, such as 
                         LIGO. More specifically, it has been developed a Multi- Nested 
                         Pendula (MNP) system with Geometric Anti-Springs (GAS). This 
                         include: studies on the center of percussion; installation of new 
                         suspensions; and also the installation of a set of GAS; besides of 
                         improving the measurement techniques of the system under very low 
                         pressures. The anti-spring effect of a GAS prototype has been 
                         observed. It is shown by experiments and simulations that the 
                         attenuation of an optimized MNP reaches up to a factor of about 
                         10,000. This factor could still be increased with a new system 
                         model.",
            committee = "Ara{\'u}jo, Jos{\'e} Carlos Neves de (presidente) and Aguiar, 
                         Odylio Denys de (orientador) and Costa, C{\'e}sar Augusto and 
                         Oliveira, Rog{\'e}rio de Moraes and Bortoli, Fabio da Silva and 
                         Fauth, Anderson Campos",
         englishtitle = "Study of the treatment of niobium cavities for the Mario Schenberg 
                         detector and performance of the Multi-Nested Pendula for use in 
                         interferometric detectors",
             language = "pt",
                pages = "145",
                  ibi = "8JMKD3MGP3W34R/3R8FL25",
                  url = "http://urlib.net/ibi/8JMKD3MGP3W34R/3R8FL25",
           targetfile = "publicacao.pdf",
        urlaccessdate = "26 abr. 2024"
}


Fechar