@PhDThesis{Ferreira:2018:EsTrCa,
author = "Ferreira, {\'E}lvis Camilo",
title = "Estudo do tratamento de cavidades de ni{\'o}bio para o detector
Mario Schenberg e do desempenho do Multi-Nested Pendula para uso
em detectores interferom{\'e}tricos",
school = "Instituto Nacional de Pesquisas Espaciais (INPE)",
year = "2018",
address = "S{\~a}o Jos{\'e} dos Campos",
month = "2018-05-30",
keywords = "ondas gravitacionais, detectores, isolamento vibracional,
multi-nested pendula, antimolas geom{\'e}tricas, transdutores,
gravitational waves, detectors, vibrational isolation,
Multi-Nested Pendula, geometric antisprings, transducers.",
abstract = "Neste trabalho, apresenta-se o desenvolvimento de instrumentos
para aumentar a sensibilidade de detectores de ondas
gravitacionais. Foi realizada uma investiga{\c{c}}{\~a}o para
otimizar o fator de qualidade el{\'e}trico de cavidades de
ni{\'o}bio, dos transdutores do detector esf{\'e}rico Mario
Schenberg. Processos de ataque qu{\'{\i}}mico por
solu{\c{c}}{\~a}o {\'a}cida e implanta{\c{c}}{\~o}es
i{\^o}nicas por imers{\~a}o em plasma de nitrog{\^e}nio nas
superf{\'{\i}}cies das cavidades foram feitos. O maior fator
obtido foi de cerca de 60 mil. Observa-se que baixos percentuais
at{\^o}micos de nitrog{\^e}nio na superf{\'{\i}}cie s{\~a}o,
provavelmente, um requisito para obten{\c{c}}{\~a}o de altos
fatores de qualidade el{\'e}tricos. Apresenta-se, tamb{\'e}m,
uma investiga{\c{c}}{\~a}o sobre o ru{\'{\i}}do vibracional
tilt de solo induzido pelo vento, no observat{\'o}rio LIGO de
Livingston. Neste trabalho, tamb{\'e}m {\'e} descrito o
desenvolvimento de instrumentos de isolamento vibracional passivo,
para as massas de teste (espelhos) de detectores
interferom{\'e}tricos de ondas gravitacionais, como o LIGO. Mais
especificamente, de um sistema pendular multi-aninhado (MNP) com
antimolas geom{\'e}tricas (GAS). O desenvolvimento incluiu:
estudos sobre o centro de percuss{\~a}o; instala{\c{c}}{\~a}o
de novas suspens{\~o}es; e, tamb{\'e}m, a instala{\c{c}}{\~a}o
de um conjunto de GAS; al{\'e}m da melhora das t{\'e}cnicas de
medi{\c{c}}{\~a}o do sistema em v{\'a}cuo. O efeito antimola de
um prot{\'o}tipo GAS foi observado. Mostra-se, atrav{\'e}s dos
experimentos e das simula{\c{c}}{\~o}es, que a
atenua{\c{c}}{\~a}o do MNP otimizado, chega at{\'e} um fator da
ordem de 10.000. Esse fator ainda poderia ser aumentado com um
novo modelo do sistema. ABSTRACT: In this work, we present the
development of instruments to increase the sensitivity of
gravitational wave detectors. An investigation was carried out to
optimize the electrical Q factor of niobium transducers cavities
of the Mario Schenberg spherical antenna. Chemical processes, and
nitrogen plasma immersion ion implantation on cavities surfaces
were done. The largest Q factor measured was about 60k. It is
observed that low atomic percentages of nitrogen in the surface
probably are a requirement for obtaining high electrical Q
factors. We also present an investigation on the vibrational noise
of the ground-tilt induced by wind in the LIGO Livingston
Observatory. In this work, we also describe the development of
passive vibrational isolation instruments for the test masses
(mirrors) of interferometric gravitational wave detectors, such as
LIGO. More specifically, it has been developed a Multi- Nested
Pendula (MNP) system with Geometric Anti-Springs (GAS). This
include: studies on the center of percussion; installation of new
suspensions; and also the installation of a set of GAS; besides of
improving the measurement techniques of the system under very low
pressures. The anti-spring effect of a GAS prototype has been
observed. It is shown by experiments and simulations that the
attenuation of an optimized MNP reaches up to a factor of about
10,000. This factor could still be increased with a new system
model.",
committee = "Ara{\'u}jo, Jos{\'e} Carlos Neves de (presidente) and Aguiar,
Odylio Denys de (orientador) and Costa, C{\'e}sar Augusto and
Oliveira, Rog{\'e}rio de Moraes and Bortoli, Fabio da Silva and
Fauth, Anderson Campos",
englishtitle = "Study of the treatment of niobium cavities for the Mario Schenberg
detector and performance of the Multi-Nested Pendula for use in
interferometric detectors",
language = "pt",
pages = "145",
ibi = "8JMKD3MGP3W34R/3R8FL25",
url = "http://urlib.net/ibi/8JMKD3MGP3W34R/3R8FL25",
targetfile = "publicacao.pdf",
urlaccessdate = "26 abr. 2024"
}