Resultado da Pesquisa
A expressão de busca foi <related:sid.inpe.br/plutao/2016/12.05.19.27.01-0:en:title:2:prototype corneal transportation new:evaluation new prototype corneal transportation eye banking:>.
1 referência similar encontrada (inclusive a original) buscando em 17 dentre 17 Arquivos.
Data e hora local de busca: 20/04/2024 10:30.
1. Identificação
Tipo de ReferênciaArtigo em Revista Científica (Journal Article)
Siteplutao.sid.inpe.br
Código do Detentorisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
Identificador8JMKD3MGP3W/3MTN3TB
Repositóriosid.inpe.br/plutao/2016/12.05.19.27   (acesso restrito)
Última Atualização2016:12.13.14.55.42 (UTC) lattes
Repositório de Metadadossid.inpe.br/plutao/2016/12.05.19.27.01
Última Atualização dos Metadados2021:02.03.17.56.09 (UTC) administrator
ISSN2161-5446
Rótulolattes: 8464326901644595 4 SilvaForSanSutSat:2016:EvNePr
Chave de CitaçãoSilvaForSanSutSat:2016:EvNePr
TítuloEvaluation of new prototype for corneal transportation in eye banking
Ano2016
MêsMar.
Data de Acesso20 abr. 2024
Tipo de Trabalhojournal article
Tipo SecundárioPRE PI
Número de Arquivos1
Tamanho837 KiB
2. Contextualização
Autor1 Silva, Nátalie Stéphanie Miguel
2 Forseto, Adriana dos Santos
3 Santos, Vagner Rogério dos
4 Suterio, Ricardo
5 Sato, Elcio Hideo
Identificador de Curriculo1
2
3
4 8JMKD3MGP5W/3C9JJ62
Grupo1
2
3
4 LIT-LIT-INPE-MCTI-GOV-BR
Afiliação1 Universidade de São Paulo (USP)
2 Sorocaba Ophthalmologic Hospital
3 COGNI Company of São José dos Campos
4 Instituto Nacional de Pesquisas Espaciais (INPE)
5 Universidade de São Paulo (USP)
Endereço de e-Mail do Autor1
2
3
4 ricardo.suterio@inpe.br
RevistaThe International Journal of Eye Banking
Volume4
Número1
Páginas1-5
Histórico (UTC)2016-12-13 14:55:42 :: lattes -> administrator :: 2016
2021-02-03 17:56:09 :: administrator -> simone :: 2016
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Tipo do ConteúdoExternal Contribution
Tipo de Versãopublisher
Palavras-Chavecorneal transplant
Peltier effect
thermal box
transport of the cornea
shipping containers
ResumoPurpose: To assess thermal control of a new prototype for transporting donor corneas and compare it to the traditional method. Methods: The prototype, comprised of a Peltier effect cell, was compared to a polypropylene thermal box containing a vegetable cellulose-based refrigerant thermogel, preservative, and water wrapped in polyethylene rigid packaging. The required temperature for corneal transport (2°-8°C) was measured. Both methods were monitored four times for thermal stability based on temperature measurements every 30 minutes for 36 hours. The measurements were recorded and compared using a data logger. Results: The mean latency period for reaching 8°C was 21.0 ± 1.4 minutes for the polypropylene thermal box and 19.0 ± 1.0 minutes for the prototype. The prototype had an average thermal stability of 2.6 ± 0.5ºC without a gradual temperature increase. In two of the four measurements, the assessed values were within the range of 2ºC to 8ºC. In the polypropylene box, the upper limit was exceeded after an average of 14.8 ± 4.0 hours (range, 10-19 hours) and the temperature increased was gradual and irreversible. Conclusion: The prototype maintained the thermal stability within a recommended temperature range for 36 hours, which was superior to the results obtained with the polypropylene thermal box. The prototype may be more suitable for corneal transportation over long distances and internationally.
ÁreaETES
Arranjourlib.net > Fonds > Produção anterior à 2021 > COLIT > Evaluation of new...
Conteúdo da Pasta docacessar
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreementnão têm arquivos
4. Condições de acesso e uso
Idiomaen
Arquivo Alvosilva_evaluation.pdf
Grupo de Usuárioslattes
Grupo de Leitoresadministrator
lattes
Visibilidadeshown
Permissão de Leituradeny from all and allow from 150.163
Permissão de Atualizaçãonão transferida
5. Fontes relacionadas
Repositório Espelhourlib.net/www/2011/03.29.20.55
Unidades Imediatamente Superiores8JMKD3MGPCW/444BQ9E
URL (dados não confiáveis)http://eyebankingjournal.org/article/evaluation-new-prototype-corneal-transportation-eye-banking/
Acervo Hospedeirodpi.inpe.br/plutao@80/2008/08.19.15.01
6. Notas
Campos Vaziosalternatejournal archivingpolicy archivist callnumber copyholder copyright creatorhistory descriptionlevel dissemination doi e-mailaddress format isbn lineage mark nextedition notes orcid parameterlist parentrepositories previousedition previouslowerunit progress project rightsholder schedulinginformation secondarydate secondarykey secondarymark session shorttitle sponsor subject tertiarymark tertiarytype
7. Controle da descrição
e-Mail (login)simone
atualizar