TitleRadiation errors in temperature measurements with thermocouples in a cylindrical combustor
Year1990
MonthSep - Oct
Access Date2024, Apr. 28
Secondary TypePRE PI
Number of Files1
Size1196 KiB
2. Context
Author1 Carvalho Júnior, João Andrade de
2 Santos, Wilson Fernando Nogueira dos
Resume Identifier1
2 8JMKD3MGP5W/3C9JJCC
Group1 LCP-INPE-BR
2 LCP-INPE-BR
Affiliation1 Instituto Nacional de Pesquisas Espaciais
JournalInternational Communications in Heat and Mass Tranfer
Volume17
Number5
Pages663-673
History (UTC)2005-05-10 17:31:11 :: ignes -> administrator ::
2006-11-09 18:03:18 :: administrator -> ignes ::
2007-03-07 11:39:17 :: ignes -> administrator ::
2008-06-29 02:12:58 :: administrator -> ignes ::
2008-07-03 19:03:34 :: ignes -> administrator ::
2012-11-24 01:38:43 :: administrator -> ignes :: 1990
2013-02-20 14:54:13 :: ignes -> administrator :: 1990
2021-07-28 22:35:42 :: administrator -> marciana :: 1990
3. Content and structure
Is the master or a copy?is the master
Content Stagecompleted
Transferable1
Content TypeExternal Contribution
KeywordsCOMBUSTÃO
thermocouple temperature
measurements
cylindrical combustor
AbstractThis paper presents a study on the accuracy of thermocouple temperature measurements in a cylindrical combustor. A conservative procedute to compute maximum radiation errors is described. The study shows that radiation errors not only depend on the size and emissivity of the probe and on its location relative to the combustion zone, but aldo on the mass flow rate of the gases in which the probe is immersed. Results for a particular case are presented in graphical form as function of different parameters that influence radiation errors.
AreaCOMB
Arrangementurlib.net > BDMCI > Fonds > Produção anterior à 2021 > LABCP > Radiation errors in...
doc Directory Contentaccess
source Directory Contentthere are no files
agreement Directory Contentthere are no files
4. Conditions of access and use
Languageen
Target Fileradiation.pdf
User Groupadministrator
ignes
Visibilityshown
Copy HolderSID/SCD
Archiving Policydenypublisher denyfinaldraft24
Read Permissiondeny from all and allow from 150.163
5. Allied materials
Next Higher Units8JMKD3MGPCW/3ET38CH
DisseminationWEBSCI; PORTALCAPES; COMPENDEX.
Host Collectionlcp.inpe.br/ignes/2004/02.12.18.39
cptec.inpe.br/walmeida/2003/04.25.17.12
6. Notes
Empty Fieldsalternatejournal archivist callnumber copyright creatorhistory descriptionlevel documentstage doi e-mailaddress electronicmailaddress format isbn label lineage mark mirrorrepository nextedition notes orcid parameterlist parentrepositories previousedition previouslowerunit progress project readergroup rightsholder schedulinginformation secondarydate secondarymark session shorttitle sponsor subject tertiarymark tertiarytype typeofwork url versiontype
7. Description control
e-Mail (login)marciana
update 


Close