TitleLangmuir probe measurements in TBR-1 Tokamak
ProjectFísica Básica de plasma
Year1990
Access Date2024, Apr. 27
Secondary TypePRE PN
Number of Files1
Size253 KiB
2. Context
Author1 Silva, R. P. da
2 Dallaqua, Renato Sergio
3 Nascimento, I. C.
Resume Identifier1
2 8JMKD3MGP5W/3C9JJ5K
Group1 LAP-INPE-BR
Affiliation1
2 Instituto Nacional de Pesquisas Espaciais (INPE)
3 Universidade de São Paulo. Instituto de Física
JournalRevista de Física Aplicada e Instrumentação
Volume5
Number2
Pages175-193
History (UTC)2006-05-22 14:09:10 :: vinicius -> administrator ::
2009-08-12 00:26:09 :: administrator -> vinicius ::
2010-02-04 16:57:15 :: vinicius -> administrator ::
2018-06-05 01:28:59 :: administrator -> marciana :: 1990
3. Content and structure
Is the master or a copy?is the master
Content Stagecompleted
Transferable1
Content TypeExternal Contribution
KeywordsElectrostatic probes
tokamak devices
AbstractLangmuir probes are intensively use in the plasma edge of tokamak machines for electron temperature, density and plasma potential measurements. This method is increasingly being because of recent results indicating that physical processes occuring in the plasma edge influence the plasma core properties. This work describes a Langmuir probe system that is in use in TBR-1, a small tokamak in operation at Institute of Physics of the University of São Paulo. The methodology used in the determination of plasma parameters from a charecteristics curve is shown. We then describe the experimental arrangements that are basicaly composed of a Langmuir probe and a voltage generator making possible to drive the probe with adjustable ramp voltage of -100V to +100V, with period adjustable from 50 us to 50ms. The maximum permissible current is 250mA. Incorporating a current transformer, the system allows a probe current resolution of 20uA. The system can be used in two modes: iion saturation and sweep mode. All the electronics were designed at the Laboratory. Probe voltage and current time profiles are shown and plasma parameters determined.
AreaFISPLASMA
Arrangementurlib.net > BDMCI > Fonds > Produção anterior à 2021 > LABAP > Langmuir probe measurements...
doc Directory Contentaccess
source Directory Contentthere are no files
agreement Directory Contentthere are no files
4. Conditions of access and use
Languageen
Target Filesilva-langmuir.pdf
User Groupadministrator
vinicius
Visibilityshown
Copy HolderSID/SCD
Archiving Policydenypublisher denyfinaldraft
Read Permissiondeny from all and allow from 150.163
5. Allied materials
Next Higher Units8JMKD3MGPCW/3ET2RFS
DisseminationPORTALCAPES
Host Collectionsid.inpe.br/banon/2003/08.15.17.40
6. Notes
Empty Fieldsalternatejournal archivist callnumber copyright creatorhistory descriptionlevel documentstage doi e-mailaddress electronicmailaddress format isbn label lineage mark mirrorrepository month nextedition notes orcid parameterlist parentrepositories previousedition previouslowerunit progress readergroup rightsholder schedulinginformation secondarydate secondarymark session shorttitle sponsor subject tertiarymark tertiarytype typeofwork url versiontype
7. Description control
e-Mail (login)marciana
update 


Close