TitleProgress report on the development of a very high sensitivity parametric transducer for the Mario Schenberg Gravitational wave detector
Year2006
Access Date2024, Apr. 28
Secondary TypePRE PI
Number of Files1
Size872 KiB
2. Context
Author1 Furtado, Sérgio Ricardo
2 Aguiar, Odylio Denys de
3 Almeida, Daniel S.
Resume Identifier1 8JMKD3MGP5W/3C9JJ8C
2 8JMKD3MGP5W/3C9JJ2A
Group1 DAS-INPE-MCT-BR
2 DAS-INPE-MCT-BR
Affiliation1 Instituto Nacional de Pesquisa Espaciais, Divisão de Astrofísica (INPE.DAS)
2 Instituto Nacional de Pesquisa Espaciais, Divisão de Astrofísica (INPE.DAS)
3 Centro Técnico Aeroespacial
JournalJournal of Physics: Conference Series
Volume32
Number1
Pages439-444
History (UTC)2006-08-02 12:21:39 :: simone -> administrator ::
2009-08-12 01:02:06 :: administrator -> simone ::
2011-05-29 02:52:41 :: simone -> administrator ::
2012-07-17 12:47:36 :: administrator -> banon :: 2006
2012-09-27 18:28:29 :: banon -> administrator :: 2006
2018-06-05 01:16:54 :: administrator -> marciana :: 2006
3. Content and structure
Is the master or a copy?is the master
Content Stagecompleted
Transferable1
Content TypeExternal Contribution
AbstractWe have constructed the Mario Schenberg gravitational wave detector at the Physics Institute of the University of Sao Paulo as programmed by the Brazilian Graviton Project, under the full support of FAPESP (the São Paulo State Foundation for Research Support). We are ready to do a first test run of the spherical antenna at 4.2K with three parametric transducers and an initial target sensitivity of h~10-21Hz-½ in a 60Hz bandwidth around 3.2kHz. The parametric transducers to be used on the Mario Schenberg detector consist of reentrant klystron copper-aluminum cavities covered with a thin layer of niobium on the walls and on the oscillating membrane. The gap between the central conical post and the membrane is about 40µm. Here we present a progress report on this transducer development related with niobium layer deposition in the transducer cavities and on the design of silicon membranes for the last transducer mechanical mode.
AreaCEA
Arrangementurlib.net > BDMCI > Fonds > Produção anterior à 2021 > DIDAS > Progress report on...
doc Directory Contentaccess
source Directory Contentthere are no files
agreement Directory Contentthere are no files
4. Conditions of access and use
Languageen
Target FileProgress report on the development.pdf
User Groupadministrator
banon
simone
Visibilityshown
Copy HolderSID/SCD
Archiving Policydenypublisher denyfinaldraft12
Read Permissiondeny from all and allow from 150.163
5. Allied materials
Next Higher Units8JMKD3MGPCW/3ETR8EH
DisseminationWEBSCI; PORTALCAPES; COMPENDEX.
Host Collectionsid.inpe.br/banon/2003/08.15.17.40
6. Notes
Empty Fieldsalternatejournal archivist callnumber copyright creatorhistory descriptionlevel documentstage doi e-mailaddress electronicmailaddress format isbn keywords label lineage mark mirrorrepository month nextedition notes orcid parameterlist parentrepositories previousedition previouslowerunit progress project readergroup rightsholder schedulinginformation secondarydate secondarymark session shorttitle sponsor subject tertiarymark tertiarytype typeofwork url versiontype
7. Description control
e-Mail (login)marciana
update 


Close