TitleTwo-dimensional diagnostics of edge and divertor region of toroidal helical plasmas using a lithium beam probe
Year2003
Access Date2024, May 02
Secondary TypePRE PI
Number of Files1
Size122 KiB
2. Context
Author1 Nakamura, K.
2 Iguchi, H.
3 Ueda, Mário
4 Morisaki, T.
5 Isobe, M.
6 Ida, K.
7 Takahashi, C.
8 Okamura, S.
9 Matsuoka, K.
Group1
2
3 LAP-INPE-MCT-BR
Affiliation1 The Graduate University for Advanced Studies, Japan
2 National Institute for Fusion Science, Japan
3 Instituto Nacional de Pesquisas Espaciais (INPE)
4 National Institute for Fusion Science, Japan
5 National Institute for Fusion Science, Japan
6 National Institute for Fusion Science, Japan
7 National Institute for Fusion Science, Japan
8 National Institute for Fusion Science, Japan
9 National Institute for Fusion Science, Japan
Author e-Mail Address1 nkiichi@nifs.ac.jp
2
3 ueda@plasma.inpe.br
JournalJournal of Nuclear Materials
Volume313-316
Pages725-728
History (UTC)2013-03-11 18:39:08 :: administrator -> marciana :: 2003
2013-04-15 14:23:41 :: marciana -> administrator :: 2003
2018-06-05 01:20:45 :: administrator -> marciana :: 2003
3. Content and structure
Is the master or a copy?is the master
Content Stagecompleted
Transferable1
Content TypeExternal Contribution
Version Typepublisher
KeywordsLiBP
two-dimensional diagnostics
divertor region
CHS
AbstractA two-dimensional neutral lithium beam probe has been designed and installed on the Compact Helical System (CHS) to study the edge and separatrix region of l ¼ 2 helical divertor con.guration. A 1020 keV beam with equivalent neutral beam current of 0.1 mA is injected. Light emission from the injected beam by electron impact excitation (LiI/670.8 nm) is collected by an eight-channel detector system using optical band-pass .lters and Avalanche Photodiodes. The injection beam line is mechanically tilted to cover the area two-dimensionally. The total system has been calibrated by injecting the beam into the helium-gas-.lled CHS vacuum chamber. Detailed measurements of twodimensional structure of edge and divertor region are expected to contribute to studies of helical divertor concept and to improve understanding of the role of edge plasmas on core confinement as well.
AreaFISPLASMA
doc Directory Contentaccess
source Directory Contentthere are no files
agreement Directory Contentthere are no files
4. Conditions of access and use
Languageen
Target File1-s2.0-S0022311502014885-main.pdf
User Groupadministrator
marciana
Visibilityshown
Copy HolderSID/SCD
Archiving Policydenypublisher denyfinaldraft24
Read Permissiondeny from all and allow from 150.163
Update Permissionnot transferred
5. Allied materials
Next Higher Units8JMKD3MGPCW/3ET2RFS
DisseminationWEBSCI
Host Collectionsid.inpe.br/banon/2003/08.15.17.40
6. Notes
Empty Fieldsalternatejournal archivist callnumber copyright creatorhistory descriptionlevel e-mailaddress format isbn label lineage mark mirrorrepository month nextedition notes number orcid parameterlist parentrepositories previousedition previouslowerunit progress project readergroup resumeid rightsholder schedulinginformation secondarydate secondarymark session shorttitle sponsor subject tertiarymark tertiarytype typeofwork url
7. Description control
e-Mail (login)marciana
update 


Close